Issue Descriptions
The DJI Terra offline version prompts the error message “No permission to use. Go to the official website or contact your local dealer to purchase”.
Cause of Issue
This error has the same reason as that of the online version, i.e., the current system time is not within the valid time period for the license.
Solutions
If your computer can connect to the Internet:
1. Please update the CodeMeter certification time after connecting to the Internet.
2. Please update the current Windows system time.
3. After the update is complete, click WebAdmin on the CodeMeter main interface, and go to Container to check whether the System Time (PC) matches the System Time (CmContainer). (The acceptable time difference is less than 3 minutes.) The issue is solved if the time is normal.
If your computer cannot connect to the Internet:
1. Open the CodeMeter interface and click WebAdmin to go to the web management interface.
2. On the Container tab, find the activated container and check the time difference between System Time (PC) and System Time (CmContainer).

3. If the CmContainer time is ahead of the system time, one option is to terminate the CodeMeter service (or just power off the computer) and wait for a time longer than the time difference to start the service again. When the CodeMeter service starts, it will match the CmContainer time and system time, and the certificate will be restored to normal.
If you are not choosing to power off the computer when the service is shut down, please do not run DJI Terra or any other software which rely on CodeMeter service, as this may autorun CodeMeter service.

4. If the CmContainer time is behind the system time, please restart the CodeMeter service to match the CmContainer time with the system time.

5. Go to the web management interface again to check if the time difference is within the permissible range.